characteristics
of high reliability
·double conversion on-line topology structure design, make UPS output for frequency tracking, phase-locked, voltage regulator and filter the noise, not affected by power fluctuation interference of pure sine wave power, so that the UPS for the user device to provide more comprehensive and perfect protection.
·output zero transition time, meet the sophisticated equipment to power a high standard.
·modular design and dual CPU control, the reliable operation, high stability, guarantee the safe operation of the whole efficiency of UPS.
reliability
Pure online static bypass technique, provides strong overload and fault protection device.
Built-in manual repair bypass, to further improve the reliability of continuous running load.
Environmental adaptability
UPS of the AC input voltage range up to 380V ( or 400V )±20 ﹪, thereby reducing the battery usage frequency, greatlyprolongs the service life of the cell.
UPS input frequency range, to ensure access to various fuel generator can work stably.
of high
The intelligent battery management function ( ABM ) technology, thereby prolonging the service life of the battery, reduce the number of battery maintenance.
Advanced automatic conversion of constant current and constant voltage charging technology, the maximum activationcell, save the charging time, prolongs the service life of the cell.
protection
With a boot from the diagnosis function, avoid pitfalls and UPS may trigger failure risk.
With the AC input over / under voltage protection; output overload, short circuit protection; inverter over-temperature protection, battery undervoltage warning / protection, battery charging protection and comprehensive protection function,greatly ensure the system stability and reliability.
·strong overload capacity, in the 110%/125%/150% overload can maintain 300 minutes /10 minutes / 1 minutes.
capability
·insert and machine module ( optional) can achieve up to 6 units and machine, increases the reliability of the system. The system is scalable, easy to realize and machine.
And UPS can share the same set of backup battery.
·fixed master-slave relationship and the machine: in several parallel UPS, wherein the first boot the a (Master ) UPS, the other mainly from (Slave) UPS, UPS master-slave interchangeable, if a UPS inverter fault occurs, the UPS automatically output, the load from the remaining UPS to provide power supply.
management of human nature
LCD display panel, to the user to accurately display the working condition and the working data UPS.
Through RS232 interface with UPS intelligent monitoring software and computer communications, UPS variousparameters displayed on the communication interface of stick out a mile.
·external SNMP adapter, UPS remote network management functions, to provide real-time UPS data and power supply information, through a variety of network management system for communication and management.
Product technical parameters
Model
|
FX33160 |
FX33200 |
FX33250 |
FX33300 |
FX33400 |
Rated capacity (W )
|
160K
VA |
200K
VA |
250K
VA |
300K
VA |
400K
VA |
Rated capacity (W )
|
128KW |
160KW |
200KW |
240KW |
320KW |
Rated voltage
|
380Vac(or 400Vac) |
input |
Input voltage range
|
380Vac(or 400Vac)±20% Three phase four line input |
Input frequency range
|
50/60Hz±5Hz Automatic identification |
Power factor
|
>0.97 |
Maximum inputcurrent
|
245A |
310A |
385A |
470A |
625A |
oupput |
Output voltage
|
380Vac(or 400Vac)±1% |
Output frequency
|
Input frequency automatic tracking
|
Frequency stability ( battery mode )
|
50Hz±0.05% |
Output waveform
|
Sine wave
|
Waveform distortion
|
Linear load < 3% < 8% nonlinear load
|
Power factor
|
0.8 |
Peak factor
|
3∶1 (max) |
Overload capacity
|
In the 110%/125%/150% overload can maintain 300 minutes /10 minutes /1 minutes
|
Conversion time
|
|
Cityelectric modefor battery
|
0ms |
Bypass
|
Rated voltage
|
380Vac(or 400Vac) |
Voltage range
|
380Vac ( or 400Vac ) + 20% ( 10%15%20% adjustable )
|
Rated frequency
|
50/60Hz ( automatic identification )
|
Frequency range
|
±2%(±1% to ±5%adjustable) |
Battery
|
)
|
480 |
Panel display
|
LED |
The instruction input, inverter, bypass, battery status
|
LCD |
Display input and output voltage, frequency, battery voltage, load percentage, the temperature in the machine
|
Communications
|
Communicationinterface
|
Dry contact RS232 communication interface to the FX33O interface
|
Work environment
|
Operating temperature
|
0~40℃ |
Relative humidity
|
0~95% no condensation
|
Storage temperature
|
-25℃~55℃ |
Noise
|
< 70dB |
Physical characteristics
|
Net weight(Kg)
|
1300 |
1350 |
2200 |
2200 |
2600 |
Gross weight(Kg)
|
1400 |
1450 |
2450 |
2450 |
2900 |
size(W× D × H)mm |
1420×745×1810 |
1630×850×1900 |
1630×1000×1900 |
Option and machine module, harmonic filter, input isolation transformer, intelligent monitoring software,SNMP adapter
|
Safety standard EN50091-1 EN50091-2 Class A
|
YD/T1095-2000 implementation of standards
|